Fluorokine Cytokine Receptor Detection Kits

R&D Systems?Fluorokine Cytokine Receptor Detection Kits are for the identification of functional cytokine receptors on cell surfaces using fluorochrome-labeled cytokines. They provide a means to monitor receptor expression based on the specificity of ligand-receptor interactions by flow cytometry. This circumvents any untoward antibody reactivities due to the complexities of cytokine receptor structures, such as high and low affinity forms of receptors and the conservation of protein chains among different cytokine receptors. Fluorokine kits allow the determination of the fraction of cells bearing specific cytokine receptors.

R&D Systems?labeled cytokines are biotin- or phycoerythrin-conjugated proteins optimized for retention of biological activity and for detection of cell surface cytokine receptors. Biotinylated cytokines make use of an amplification system that allows multiple avidin-Fluorescein molecules to react with the cell-bound cytokine. This results in a brighter signal than conventional staining, while retaining the specificity of a low concentration of ligand. Fluorokine kits are compatible with fluorescent antibodies, enabling simultaneous multiparameter analysis of cells, and are ideally suited for the identification of subpopulations of cells that are differentially responsive to cytokines.

We also offer fluorochrome-conjugated antibodies for intracellular cytokine staining via flow cytometry. Intracellular cytokine staining requires that cells first be fixed and then permeabilized, allowing conjugated antibodies access to proteins within the cell. The conjugated antibody is then able to bind to its target cytokine within the cell. Following a final wash, the cells are analyzed on a flow cytometer. Flow cytometric analysis of CFS conjugates will generate a signal which can be detected in the fluorescein signal detector

(usually FL1) while R-PE conjugates will generate signal which can be monitored by the detector reserved for phycoerythrin emission (usually FL2). for more details.

 

Fluorokine Cytokine Receptor Detection Kits

Product

Catalog #

Label

Size

   

human Eotaxin

NFEO0

Biotin

100 Tests

   

human Flt-3 Ligand

NFFK0

Biotin

100 Tests

   

human G-CSF

NFCSPE

Phycoerythrin

100 Tests

   

human GM-CSF

NFGMPE

Phycoerythrin

100 Tests

   

human IL-1a

NFLA0

Biotin

100 Tests

   

human IL-1b

NFLB0

Biotin

100 Tests

   

human IL-2

NF200

Biotin

100 Tests

   

human IL-3

NF300

Biotin

100 Tests

   

human IL-4

NF400

Biotin

100 Tests

   

human IL-6

NF600

Biotin

100 Tests

   

human IL-7

NF700

Biotin

100 Tests

   

human IL-10

NF100

Biotin

100 Tests

   

mouse JE/MCP-1

NFJE0

Biotin

100 Tests

   

human LIF

NFLF0

Biotin

100 Tests

   

human MCP-1

NFCP0

Biotin

100 Tests

   

human MIP-1a

NFLD0

Biotin

100 Tests

   

human MIP-1b

NFBM0

Biotin

100 Tests

   

human SCF

NFKL0

Biotin

100 Tests

   

mouse SCF

NFMKL0

Biotin

100 Tests

   

human TGF-b

NFTG0

Biotin

100 Tests

   

human TNF-a

NFTA0

Biotin

100 Tests

   

human Tpo

NFTP0

Biotin

100 Tests

   

human VEGF

NFVE0

Biotin

100 Tests

   

Cell Surface Cytokine Staining Reagents

Reagent

Catalog #

Label

Type

Size

 

human CCR-1

FAB145B

Biotin

Mouse IgG2B
Clone # 53504.111

100 Tests

 

human CCR-2

FAB151B
FAB151P

Biotin
Phycoerythrin

Mouse IgG2B
Clone # 48607.211

100 Tests

 

human CCR-3

FAB155F
FAB155P

Fluorescein
Phycoerythrin

Rat IgG2A
Clone # 61828.111

100 Tests

 

human CCR-5

FAB180B
FAB180F

Biotin
Fluorescein

Mouse IgG2B
Clone # 45502.111

100 Tests

 

FAB181B
FAB181F

Biotin
Fluorescein

Mouse IgG2B
Clone # 45523.111

100 Tests

 

FAB182B
FAB182F
FAB182P

Biotin
Fluorescein
Phycoerythrin

Mouse IgG2B
Clone # 45531.111

100 Tests

 

FAB183B
FAB183F

Biotin
Fluorescein

Mouse IgG2B
Clone # 45549.111

100 Tests

 

human CCR-5 Sampler Pack

FABSP1

None

1 vial each of MAB180, MAB181, MAB182, MAB183

100 µg
of each

 

FABSP1FL

Fluorescein

1 vial each of FAB180F, FAB181F, FAB182F, FAB183F listed above

100 µg
of each

 

human CCR-6

FAB195P

Phycoerythrin

Mouse IgG2B
Clone # 48607.211

100 Tests

 

human CXCR-1 (IL-8 RA)

FAB330F
FAB330P

Fluorescein
Phycoerythrin

Mouse IgG2A
Clone # 49801.111

100 Tests

 

human CXCR-2 (IL-8 RB)

FAB331F
FAB331P

Fluorescein
Phycoerythrin

Mouse IgG2A
Clone # 48311.211

100 Tests

 

human CXCR-3

FAB160F

Fluorescein

Mouse IgG
Clone # 49801

100 Tests

 

human CXCR-4

FAB170B
FAB170F
FAB170P

Biotin
Fluorescein
Phycoerythrin

Mouse IgG2A
Clone # 12G5

100 Tests

 

FAB171B

Biotin

Mouse IgG2A
Clone # 44708.111

100 Tests

 

FAB172B

Biotin

Mouse IgG2B
Clone # 44716.111

100 Tests

 

FAB173B
FAB173P

Biotin
Phycoerythrin

Mouse IgG2B
Clone # 44717.111

100 Tests

 

human CXCR-4 Sampler Pack

FABSP2

None

1 vial each of MAB171, MAB172, MAB173

100 µg
of each

 

FABSP2B

Biotin

1 vial each of FAB170B, FAB171B, FAB172B, FAB173B listed above

100 µg
of each

 

human CXCR-5 (BLR-1)

FAB190B
FAB190P

Biotin
Phycoerythrin

Mouse IgG2B
Clone # 51505.111

100 Tests

 

human IL-1a

FAB200F

Fluorescein

Mouse IgG1
Clone # 3401

50 Tests

 

human IL-18 R

FAB840P

Phycoerythrin

Mouse IgG1
Clone # 70625.111

100 Tests

 

human STRL33/BONZO

FAB669P

Phycoerythrin

Mouse IgG2B
Clone # 56811

100 Tests

 

human TNF-a

FAB210F

Fluorescein

Mouse IgG1
Clone # 6401

50 Tests

 

human TNF RI

FAB225F
FAB225P

Fluorescein
Phycoerythrin

Mouse IgG1
Clone # 16803.161

100 Tests

 

human TNF RII

FAB226F
FAB226P

Fluorescein
Phycoerythrin

Mouse IgG2A
Clone # 22235.3

100 Tests

 

Additional Flow Cytometry Reagents

StatusFlow?Whole Blood Control is a stable reference control for the complete process of lymphocyte immunophenotyping by flow cytometry. StatusFlow monitors instrument set-up and performance, RBC lysis, antibody staining, and data analysis. This whole blood control, which is used exactly as a sample of freshly drawn blood, is compatible with many reagent and instrument systems. StatusFlow assay values are reported as percent of total lymphocytes and as absolute number of cells of the following phenotypes: CD3+, CD3+/CD4+, CD3+/CD8+, CD19+ and CD3-/CD16+56+. Please inquire for additional phenotypes. StatusFlow is for in vitro diagnostic use. For more information on StatusFlow, visit the StatusFlow website at www.StatusFlow.com.

Additional Flow Cytometry Reagents
Reagent Catalog # Label Size
StatusFlow Whole Blood Control FC202
FC402
FC204
FC404
None 25 Tests
50 Tests
80 Tests
160 Tests
Whole Blood Lyse Kit WL-1000 None 250 Tests
Avidin-
Fluorescein
F0030 Carboxyfluorescein
derivative of avidin
100 Tests
Streptavidin-
Phycoerythrin
F0040 R-phycoerythrin
derivative of streptavidin
100 Tests

Back to Top

TWC Biosearch International

This page is  best viewed with ANY browser.